Following local government guidelines, we've taken various safety measures to protect our site staff due to 2019-nCoV. NEUROSPEC Online remains open and we aim to deliver within the outlined delivery times.
No Additional Credit Card or PayPal Fees
Prices Lower than Regular Pricelist Prices
Fast Support Reply

Electro Stimulation

View as Grid List
Sort by
Display per page

Digitimer DS2A (Constant voltage)

The DS2A Mk.II (Constant voltage) provides a precise Constant Voltage stimulus (up to 100V) controllable in Pulse Duration and Amplitude from self-contained batteries, making it ideally suited to electrophysiological recording in small preparations or cells where low noise is required. The DS2A can be triggered by an external device such as our new DG2A Train/Delay Generator. This stimulator is NOT approved for use on human subjects. The DS2A can be fitted into a 19" rack mounting frame (D121-11) which can hold up to two DS2A's, DS3's DS4's or DG2A's.

Please note: Important! This product is for research applications only. Not a medical device as defined in EU directive 93/42/EEC. Not designed or intended to be used for diagnosis or treatment of disease.

CHF 1,744.60

Digitimer DG2A - Train/Delay Generator

This small free-standing instrument has been designed for control of normal repetitive stimulation as well as for defining the Effective Refractory Period using a second, delayed pulse. This unit is especially useful as a frequency generator (as a TTL trigger source) for use with our DS2A, DS3 and DS7A isolated stimulators which have their own pulse duration controls. The basic features of it's predecessor the DG2 Trigger Generator have been extended to allow trains of pulses to be generated in response to input signals from other devices.

Please note: Important! This product is for research applications only. Not a medical device as defined in EU directive 93/42/EEC. Not designed or intended to be used for diagnosis or treatment of disease.

CHF 1,209.00

Digitimer DS3 (Constant current)

The DS3 (Constant current) provides a precise Constant Current stimulus (up to 32mA) controllable in Pulse Duration and Amplitude and as with the DS2A this output comes from self-contained batteries. The DS3 also features a "clamp" or discharge circuit which discharges the output between stimuli, preventing a charge build up on the preparation. In other constant current devices this charge build up can lead to a loss of stimulus. The DS3 can be triggered by an external device such as our new DG2A Train/Delay Generator.

Please note: Important! This product is for research applications only. Not a medical device as defined in EU directive 93/42/EEC. Not designed or intended to be used for diagnosis or treatment of disease.

CHF 2,007.20

Digitimer DS4 (Bi-phasic Stimulus Isolator)

The DS4 takes an analogue voltage waveform defined within your own data acquisition/ control system and converts it into an isolated constant current stimulus. The DS4 will accept several input voltage ranges and produces four output ranges (±10µA, ±100µA, ±1mA and ±10mA). It also features a GATE input, so that several DS4 units can be controlled by a single analogue waveform, but enabled individually via this GATE input. A timed "inactivity sensor" reduces battery usage and damaging "leak currents" during infrequent stimulation, while at the same time maintaining low levels of zero crossing distortion for repetitive waveforms. This stimulator is NOT approved for use on human subjects.

Please note: Important! This product is for research applications only. Not a medical device as defined in EU directive 93/42/EEC. Not designed or intended to be used for diagnosis or treatment of disease.

CHF 3,201.90

D185-EH2 Electrode Holder

The D185-EH2 "Depth Electrode" has 1 cathode and 3 anodes. D185-EH2 Electrode Holder comes with a 2m cable, set of 12mm felt pads and moulded plug for connection to Digitimer stimulators D185 and DS7A.
CHF 819.00

D185-EH3 Electrode Holder

The D185-EH3 "Standard Electrode", single anode and cathode of 12mm diameter, separated by 50mm. The D185-EH3 Electrode Holder comes with a 2m cable and a moulded plug for connection to Digitimer stimulators D185 / DS7A.
CHF 555.10

D185-EH4 Electrode Holder

The D185-EH4 has a single felt pad anode and cathode, separated by 60mm. The D185-EH4 Electrode Holder comes with a 2m cable, a moulded plug for connection to Digitimer stimulators D185 / DS7A and a set of 12mm felt pads.
CHF 572.00

D18X-PADS Felt Pads

Replacements 12mm felt pads for stimulator series D185-EH2 / EH3 / EH4 electrode holders, 10 pieces per pack.
CHF 62.40

PALS® Connection Cable

Electrode Adaptor Cable, with DIN 1.5mm touch proof plugs (female) at one end and 2mm pins at the other. Various cable lengths available. Supplied in pairs (one red, one black). Used to connect electrodes with 2mm sockets such as Axelgaard self adhesive electrodes or the extension cable D185-HB4.
From CHF 110.50

D185-HB1 Electrode Connection Headbox

Electrode connection headbox (4.5m cable) for the Digitimer Stimulator D185 MKII. This extension headbox provides 5 linked pairs of 1.5mm DIN sockets for connection to MEP electrodes closer to the site of stimulation.
CHF 353.60