ValuTrode® Cloth Electrodes from Axelgaard, adhesive electrode with patented MultiStick hydrogel, for electrical stimulation/neurostimulation. Size: 5cm x 9cm (rectangle). 40 x ValuTrode® Cloth Electrodes (5cm x 9cm, rectangle) per case.
The ValuTrode® Cloth Electrode (5cm x 9cm, rectangle, CF5090) is a specially engineered neurostimulation electrode from Axelgaard. The ValuTrode series presents electrodes of superior quality at a cost-effective price point. Distinguished by Axelgaard's patented multi-layer MultiStick® hydrogel, ValuTrode® electrodes are esteemed for their robustness and versatile applicability to the skin.
Each ValuTrode® cloth electrode comes pre-assembled with a 6cm lead wire which terminates in a 2mm socket (use appropriate connection cable with 2mm pin - see related products below).
The size of this ValuTrode® cloth electrode is 5cm x 9cm and of a rectangle shape. 40 ValuTrode® Cloth Electrodes (5cm x 9cm, rectangle) per case - electrodes are packed separately into packs of 4 electrodes/pack.
Technical Specifications
- Shape: Rectangle
- Size: 5cm x 9cm
- Contact Material: MultiStick® Hydrogel (patented by Axelgaard)
- Latex: Latex Free
- Use: Semi-disposable, can be re-used until hydrogel no longer adheres properly to subjects' skin
- Packaging: 10 * 4/pack = 40/case
Application Note
- Caution: Electrodes not firmly attached to the skin greatly increase the chance of burns and other adverse reactions.
- Do not apply to broken skin.
- When applying electrical stimulation, the intensity must not exceed 0.1 Watt/cm2.
- We recommend adding connection cable NS-7509 with 2mm pin to DIN 1.5mm touch-proof (TP) connector (see below).
Instruction for Use
- Prep the subject's skin with an alcohol prep pad. The subject's skin must be clean, dry, and free from any oils or lotion.
- Attach connection cable (e.g., NS-7509) to the ValuTrode® Cloth Electrode 2mm socket.
- Remove the protective liner from the electrode and save the liner for later.
- Apply ValuTrode® Cloth Electrode securely to the subject's skin. Apply center first, then smooth down to electrode edges.
- Connect the DIN 1.5mm touch-proof (TP) connector of the connection cable to the electrical stimulation device.
- Turn the electrical stimulator on and adjust it according to the electrical stimulator instructions for treatment. Do not exceed an intensity of 0.1 Watt/cm2.
- When the electrical stimulation session is complete, turn the electrical stimulator off.
- Lift at the edge of the ValuTrode® Cloth Electrode and peel to remove the electrode from the subject's skin.
- Place the adhesive side of the ValuTrode® Cloth Electrode back on the protective liner.
- Disconnect the connection cables from the electrical stimulator and ValuTrode® Cloth electrodes.
- Place the ValuTrode® Cloth electrodes back in the original package.
- Once the ValuTrode® Cloth electrodes begin losing adhesion, gently rubbing one or two drops of water onto gel surface which may extend usage. If not, replace with new electrodes.