Ag/AgCl Sintered Electrodes (with Groove)

As low as $31.28
Only %1 left
SKU
NS-7636

Standard Profile Ag/AgCl Electrode with Groove, 6mm electrode sensor diameter, 100cm lead wire length, terminates in a 1.5mm touch-proof (TP) connector. Can be used for various applications including EEG, EMG, facial EMG, EOG.

These Ag/AgCl Sintered Electrode come with a 6mm diameter and 1mm thick Ag/AgCl electrode sensor mounted in a durable epoxy ring housing that has a Groove. The groove allows for inserting the electrode into a strap or cap (e.g., EEG cap). The groove itself has a diameter of 12mm and 2.5mm in height. The height of the epoxy housing is 7mm. The epoxy coating of the housing ensures durability and a waterproof electrode. Packaging size is one Ag/AgCl sintered electrode per pack.

Ag/AgCl sintered electrodes feature a small cavity that should be filled with a conductive gel, cream, or paste. The depth of the cavity is 2mm.

This Ag/AgCl sintered electrode can be re-used when treated with care and cold sterilized after use. The lead wire length is 100cm (40”) and terminates in a DIN 1.5mm touch-proof (TP) connector. Standard lead wires are PVC insulated multi-strand copper with internal Tinsel for additional strength and durability.

These versatile Ag/AgCl sintered electrodes have the consistency of soft metal and can be re-shaped by sanding, cutting, drilling and filing. Designed for use in electrochemistry, stimulation, precision bioelectric recording, electrophysiology and neurophysiological applications.

Ag/AgCl sintered electrodes can be used as both standard and reference electrodes, due to their stability and reproducible results. Silver-Silver Chloride (Ag/AgCl) Electrodes are known for their low offset voltage, low noise and stability. Reusable and non-toxic, the electrodes can be cold sterilized and used for many years with minimal care.

 

Technical Specifications

  • Connector: DIN 1.5mm touch-proof (TP) socket (female connector)
  • Lead wire: Tinsel with PVC insulation
  • Sensor material: Sintered Ag/AgCl
  • Cable length: 100cm
  • Sensor diameter: 6mm
  • Height (housing): 7mm
  • Cavity depth: 2mm
  • Groove diameter: 12mm
  • Groove height: 2.5mm
  • Packaging: 1 Ag/AgCl Sintered Electrode (with Groove) per pack

 

Technical Features

  • Low offset voltage
  • No re-chloridizing necessary
  • Reusable and resurfacable
  • Cold sterilization possible
  • Endurable Epoxy Housing
  • Pre-assembled with a tinsel wire, terminating in a DIN 1.5mm touch-proof (TP) connector
  • Profile: Groove (size of Groove: 12mm diameter, 2.5mm height)

 

Electrical Specifications

The following values were measured between pairs of electrodes and in 0.9% saline solution. These are median values from a large sample:

DC offset Voltage (bias potential): 180 µV, Drift: 25 µV / h (at constant temperature)
Noise: 1 µV P – P (0.1 – 1 (0.1 – 1 kHz)
Polarization (counter EMF): 2 – 4µV at 0.1 µA

 