Active Electrode Sensor Set MK3 for the ActiveTwo MK3 (Active2.5) from BioSemi. Terminates in a 68-pole SCSI connector. 32 * Pin-Type active sensor with sintered Ag/AgCl tip and integrated low-noise CMOS pre-amplifier. Cable length is 140cm. Electrode sets come either with 10-20 or ABCD labels.
The Active Electrode Set MK3 is a new version of the Active Electrode Set from BioSemi B.V. MK3 electrode sets can only be used with ActiveTwo MK3 (a.k.a. Active2.5) and ActiveThree (Active3) EEG systems.
Active Electrodes Sets MK3 terminate in a 68-pole SCSI connector. Each set contains 32 pin type sensors with sintered Ag/AgCl tip and an integrated low-noise CMOS pre-amplifier with a two-wire design. The standard cable length is 140cm.
Active electrodes from BioSemi integrate an impedance converter inside the electrode itself, ensuring low-noise measurements free of interference and without any skin preparation. BioSemi active sensor electrodes can only be used with BioSemi amplifiers including the ActiveTwo and ActiveThree. Active sensor electrodes can be used for various biosignal acquisition applications including EEG, EMG, ECG, and EOG. These electrodes are pin type electrodes and fit in BioSemi EEG cap electrode holders. Electrode sets come rubberized for strain relief to avoid kinking.
NEUROSPEC offers a 24-month comprehensive and extended warranty on newly purchased MK3 active electrode sets (the standard warranty liability period is 12 months).
One Active Electrode Set MK3 for ActiveTwo MK3 (Active2.5) EEG systems per pack. The A-Set and B-Set active electrode is labelled with either standard 10-20 or ABCD labels (please select). From the C-Set through to H-Set, only ABCD labelling is available.
Features
- Active electrodes for low impedance output and low-noise measurements
- Fast application time
- Excellent long-term DC stability
- 24-month comprehensive and extended warranty (available from NEUROSPEC only)
Technical Specifications
- Cable Length: 140cm
- Connector: MK3 type 68-pole SCSI connector
- Number of Electrodes: 32 channels
- Electrode Type: Active electrodes
- Electrode Style: Pin type
- Labels: 10-20 labels or ABCD labels
- Compatibility: ActiveTwo MK3 (Active2.5) EEG systems
Instruction for Use
- Place BioSemi EEG cap on the subject's head and align it according to protocol.
- Insert conductive electrolyte gel (e.g., SIGNA gel) into EEG electrode holders on the EEG cap.
- Plug the SCSI connector of the active electrode set MK3 into the AD-Box of the ActiveTwo/ActiveThree EEG system.
- Allocate the first electrode on the active electrode set MK3.
- Allocate the corresponding EEG location on the cap.
- Plug active electrode into the corresponding EEG electrode holder.
- Repeat for the remaining EEG electrodes of that same electrode set.
- Connect the ActiveTwo/ActiveThree to the acquisition computer.
- Turn the ActiveTwo/ActiveThree system on.
- Start ActiView and navigate to the Offsets tab.
- Check the electrode offsets and add extra gel where necessary.
-
CMS/DRL External Sensor Set (Flat or Pin, ActiveThree)As low as $270.25
-
Active Sensor Electrodes (Flat or Pin)As low as $517.50
-
BioSemi Active Electrode Set (MK3, ActiveThree)As low as $1,598.50
-
BioSemi Active Electrode Set (MK2, ActiveTwo)As low as $1,598.50